Passenger Elevator with 304 Hairline Stainless Steel Cabin
Traction-driven elevator system with SUS304 stainless steel cabin panels (thickness 0.8–1.5 mm). Surface finish is hairline type with Ra 0.2–0.5 μm. System configured for mid- to high-rise buildings with traffic density ≥300 persons/hour and door cycles up to 100,000/year.
Technical Data
| Parameter | Value | Engineering Note |
|---|---|---|
| Rated Load | 630–1600 kg | 8–21 persons per trip |
| Speed | 0.5–1.75 m/s | <60m: ≤1.0 m/s typical |
| Door Width | 800–1100 mm | Hospital ≥900 mm |
| Door Height | 2000–2100 mm | Standard clearance |
| Shaft Width | 1600–2500 mm | Depends on load |
| Travel Height | ≤120 m | Gearless recommended >60m |




Application Scenarios
Hospital: cleaning frequency ≥5 cycles/day using alcohol-based agents; requires stainless steel corrosion resistance and easy surface maintenance.
Mall: door cycles ≥100,000/year; requires door operator durability and stable opening speed control.
Residential: traffic peaks during morning/evening; speed typically ≤1.75 m/s with energy-saving standby mode.
Failure → Engineering Control
Rope slip → Increase wrap angle ≥180°, maintain groove friction coefficient 0.08–0.12.
Leveling error → Encoder resolution ≥1024 ppr + VFD closed-loop control (±5 mm).
Door obstruction → Infrared curtain detection + closing force ≤150 N.
Brake wear → Dual electromagnetic brake, gap ≤0.3 mm, response time ≤0.2 s.
Panel deformation → Use ≥1.2 mm thickness for high traffic (>500 cycles/day).
Configuration Selection Guide
Load selection: 630 kg for residential (<6 floors), 1000–1600 kg for commercial buildings.
Motor type: Gearless for speed ≥1.0 m/s or travel height >60 m.
Panel thickness: 0.8 mm (<200 cycles/day), 1.2–1.5 mm (>500 cycles/day).
Material: SUS304 for indoor humidity >70%, SUS316 for chloride exposure environments.
Material Comparison
SUS201: Ni content ~1–2%, lower corrosion resistance, used in dry indoor environments.
SUS304: Ni content ~8%, balanced corrosion resistance for commercial buildings.
SUS316: Mo content 2–3%, improved resistance to chloride corrosion, used in coastal or chemical environments.
Engineering FAQ
Can SUS304 be used in coastal areas?
Only if chloride ion concentration <50 ppm; otherwise use SUS316.
How to select panel thickness?
Based on door cycles: <200/day → 0.8 mm; >500/day → ≥1.2 mm.
What is typical maintenance interval?
Rope inspection every 6 months; brake and door system every 3 months.
Submit Engineering Parameters
Provide shaft size (mm), load (kg), speed (m/s), building type, and project location for configuration.
Hot Tags: passenger elevator with 304 hairline stainless steel cabin, China passenger elevator with 304 hairline stainless steel cabin manufacturers, suppliers, factory, customized passenger elevator, outdoor elevators and lifts, elevator for gated communities, elevator for making buildings more high speed, elevator for multi story buildings, elevator with automatic doors for passengers